How Can We Help?
Home / Support Center / Knowledge Base / LED power supplies / Do I need a Junction Box in the Power Supply for LED Undercabinet Lighting?
Do I need a Junction Box in the Power Supply for LED Undercabinet Lighting?
Just want to make sure I get the power supply correct, when do I need the junction box vs not? Pairing it with the 16m 3000K LEDs, figure I need some of the small tool-less connectors as well, since they're in multiple sections, will be separating and reconnecting them. Assume I can pair all of this with an ELV/MLV Caseta dimmer for 120 bucks. Does that all sound correct?
The junction box for the dimmable power supply is generally recommended for in-wall installations to protect the unit from inadvertent exposure and contact with debris and other in-wall wiring. We would recommend consulting with your local NEC inspector to determine what regulations, if any, exist in your area.
The TRIAC dimmable power supply is compatible with forward-phase, ELV/reverse-phase and MLV dimmers. Most of the tested dimmers are forward-phase dimmers and the list of tested dimmers can be found below:
https://www.waveformlighting.com/files/DC_3093.pdf
We do offer several solderless connectors such as PN 3070 and PN 3071 which you may find useful in connecting separate LED strip runs together. Please see below for a configuration diagram showing how these components can be used:
https://www.waveformlighting.com/layoutmaps/3001_1B
Question posted under:
LED power suppliesLED strip lightsLED DriversKitchen lighting